Brochures, guides and videos.
Start with a one-minute look at each product, then the brochures, guides and training, organized by product series.
Quick looks
Each product at work, in under a minute.
DM for Liquid Cooling
From the cooling towers through the CDUs to 288 GPUs and inside a compute tray, with a CDU pump trip and the alarms going out.
DM for Power
A utility loss step by step, the generators and UPS that carry the load, a hot lithium-ion module and a branch breaker trip.
DM for Small and Midsize Data Centers
From the branch closet to the UPS room: a branch UPS on battery, a failed self-test, a ceiling unit fault and one lead-acid jar drying out.
Pythia DM Platform
The DM in 50 seconds: dashboards, alarms, trends and integration.
DM AI Connector
Claude answers from live facility data, and changes nothing without your permission.
Smart Panel IGM
Retire the SiteLink, keep the Liebert equipment.
Smart Panel AC4
Failover, changeover and staging, shown live.
Remote Status Panel
Six inputs from any equipment: an alarm, an acknowledgment and an LED test, from the panel's point of view.
UPS Remote Status Panel
A power failure, from the panel's point of view.
Remote Leak Detection Panel
A leak, an acknowledgment and a cut rope, from the panel's point of view.
MS0-MB Modbus to BACnet/IP
Modbus RTU and TCP in, native BACnet objects out, read and write.
MS0-MS Modbus to SNMP
Modbus RTU and TCP in, SNMP objects and traps out, for the network monitoring tool.
MS0-BS BACnet to SNMP
BACnet points and alarms, served as SNMP objects and traps for the NOC.
MS0-MBT and MS0-MBT3 Modbus RTU to Modbus/TCP
Serial Modbus devices on the network, with up to three systems polling at once.
CM03A 22 universal input module
22 inputs from equipment with no network port, read over Modbus or BACnet.
CM04A 8 input / 14 output module
Read points, switch relays and set analog outputs over Modbus or BACnet.
TH1 temperature and humidity sensor
Temperature and humidity on the network, with HTTP and JSON outputs and push alerts.
TH1C sensor with dry-contact input
Temperature, humidity and a leak detector contact: OPEN or CLOSED, /D and a push.
LD1 point liquid detector
Gold-plated probes catch a leak at one spot and trip an SPDT alarm contact.
LD2 sensing-rope liquid detector
Senses a leak anywhere along the rope, with a separate Trouble relay for a cut rope.
Brochures and guides
Grouped by product series. Each product lists its brochure, guide and training in one place.
Pythia DM
The monitoring platform for liquid cooling, power and the rest of the site, its AI Connector and the full DM Series Guide.
DM for Liquid Cooling
Every layer of data center liquid cooling in one console, from the cooling tower to the chip.
DM for Power
Every link from the utility to the server, with what each side would carry on failover.
DM for Small and Midsize Data Centers
Rack UPS in closets and branches, room cooling, the UPS room and every lead-acid jar, on one console.
Pythia DM platform
What DM monitors, how it alarms and trends, and how it is deployed.
DM Series Guide
Installation, configuration and operation of every DM model, in one guide.
DM AI Connector
Claude, ChatGPT or any MCP assistant, answering from live facility data.
Smart Panels
DM, IGM and AC4 controllers, prewired in a panel and ready to mount.
Smart Panel DM (SPDM)
The DM platform in a wall-mount enclosure, for rooms with no server rack. Cellular and Starlink options.
Smart Panel IGM (SPIGM)
Up to twelve Liebert units over the RS-422 IGM wiring you already have.
Smart Panel AC4 (SPAC4)
Automatic changeover, failover and temperature staging for up to four CRAC units, RTUs or pumps.
Smart Panel connections
SPDM and SPIGM power, network and field connections, for engineers and IT.
Smart Panels Guide
One guide covering every Smart Panel, written for AI assistants.
Status Panels
Remote LED, buzzer and relay panels for UPS systems, leak detection and any dry-contact equipment.
Remote Status Panel (CS0-RSP-06)
Six dry-contact inputs from any equipment, each with an LED and label, a buzzer and a summary alarm relay.
UPS Remote Status Panel
Six UPS conditions on LEDs, with an alarm you can hear, up to 1,000 feet from the UPS.
Remote Leak Detection Panel
Six leak zones with LEDs, labels and relays, plus built-in power for the detectors.
Remote Status Panels Guide
One guide covering every status panel, written for AI assistants.
Gateways
Protocol converters for one fixed connection between two systems.
MS0-MB Modbus to BACnet/IP
Modbus RTU and Modbus TCP devices presented to the BMS as native BACnet/IP objects.
MS0-MS Modbus to SNMP
Modbus RTU and Modbus TCP equipment served as SNMP objects, with traps, for SolarWinds or another network monitoring tool.
MS0-BS BACnet to SNMP
BACnet/IP and BACnet MS/TP building alarms and points served as SNMP objects for the NOC.
MS0-MBT and MS0-MBT3 Modbus RTU to Modbus/TCP
Serial Modbus devices on RS-485 or RS-232 reachable as Modbus/TCP, with nothing translated.
Accessories
Sensors, I/O modules and leak detectors that work with the DM, the panels or on their own.
TH1 and TH1C temperature and humidity sensors
Network sensors with their own web page, HTTP and PRTG JSON outputs; the TH1C adds a dry-contact input.
TS1 10K wall temperature sensor
The Type II 10K wall sensor included with each Smart Panel AC4.
Training videos
Step-by-step training for operators, administrators, contractors and installers.
DM Series
For operators and administrators, in order.
DM training 1: getting around
The console, locations and groups, live group pages, unit pages and search, for operators and administrators.
DM training 2: alarms
An alarm from start to finish: the Active list, acknowledging, clearing, history, settings and testing.
DM training 3: trends
Trend buckets, reading a chart, chart styles, exporting for reports and choosing what to trend.
DM training 4: notifications
Automations, email recipients, SNMP traps, time exceptions, the daily heartbeat and testing delivery.
DM training 5: devices and units
A SPAC4 added over Modbus/TCP, SNMP and BACnet/IP: monitoring networks, unit properties, data points, alarms and controls.
DM training 6: mappings and BMS
Publishing DM to a BMS over BACnet/IP, Modbus/TCP and SNMP: unit numbers, point numbering and exporting for integrators.
DM training 7: customizing DM
Your own images on the site, location and group pages, and custom HTML pages (beta).
DM training 8: users and network
Users and access levels, password policies, access control, network interfaces, time, backups and updates.
DM training 9: AI Connector
Connect an AI assistant such as Claude to DM: API accounts, policies, a real control change and alarm acknowledgment, and custom pages.
Smart Panels
Installation and setup, for contractors and installers.
SPAC4 installation and setup training
Wiring, network setup, configuration and commissioning, for contractors and installers.
Status Panels
Installation and setup, for contractors and installers.
Remote Status Panel installation training
Mounting, field wiring, input setup, BMS connections and testing, for contractors and installers.
UPS Remote Status Panel installation training
Wiring, a relay card example, Modbus and testing, for contractors and installers.
Leak detection panel installation training
Zone and relay wiring, LD1 and LD2 detectors, BMS connections and testing, for contractors and installers.
Guides for AI assistants
Plain-text versions of our guides, written so Claude, ChatGPT, Copilot or any AI assistant can answer installation and setup questions accurately. Download a file and add it to your chat or project, then ask your question.
Posters
Print-ready posters for the control room, the NOC or the trade show booth. Each comes in 24 x 36 in, 17 x 22 in and letter size.
From the cooling tower to the chip. Every loop, one DM.
Liquid cooling in one DM, from cooling towers and water treatment to CDUs, GPU racks and the cold plates inside each compute tray.
From the utility to the server. Every watt, one DM.
The complete power chain in one DM, from utility service, generators and UPS to PDUs, rack PDUs and each server's power supplies.
Lithium-ion or lead-acid. Every battery, watched.
UPS battery monitoring in the DM: the UPS room, lithium-ion cabinets and lead-acid strings, read from the UPS and the battery monitoring system already installed.
Ask your facility. It answers from live data.
The DM AI Connector: plain-English questions, AI-made trend charts and DM-specific dashboards built by AI, from live DM data.