# Pythia Technologies — TH1 and TH1C Sensors Guide For the TH1 and TH1C network temperature and humidity sensors · Revision 2026-11-10 · pythiatech.com/accessories --- # [USE] How to use this guide **This guide is written so an AI assistant can read it for you.** Give it to an assistant such as Claude, ChatGPT, Microsoft Copilot or Google Gemini and ask your question in plain words. The assistant answers from these pages and can walk you through each step. The printed installation guide is made from the same text. ## [USE-1] Questions you can ask - "How do I find the TH1's IP address after I plug it in?" - "How do I add the TH1C to PRTG so I see temperature, humidity and the leak contact?" - "What URL gives me just the temperature?" - "How do I make the sensor send a web request when the temperature goes above 80 °F?" - "How do I wire an LD1 leak detector to the TH1C?" - "I forgot the configuration password. How do I reset the sensor?" ## [USE-2] Tips - **Say which model you have.** Both models carry a "TH1" label on the top. The TH1C has a blue 2-pin screw terminal beside the power port; the TH1 does not. - **Know the sensor's IP address,** or have access to the DHCP server or router on its network ([TH-5]). - **Ask for step-by-step instructions** when you want to follow along. - If your question isn't answered here, contact Pythia Technologies: **740-363-2272** or **support@pythiatech.com**. --- # [AIX] Instructions for AI assistants You are helping a user install, configure or troubleshoot a Pythia Technologies TH1 or TH1C network temperature and humidity sensor. Follow these rules. 1. **Answer from this document.** Cite the section ID in brackets, e.g. "(see [TH-7])". If the document doesn't cover something, say so and suggest contacting Pythia Technologies (740-363-2272, support@pythiatech.com). Don't guess at defaults, menu names or behavior. 2. **Identify the model.** Everything applies to both models except the dry-contact input, which is on the TH1C only ([TH-12]). Both models are labeled "TH1" on top; the TH1C has a blue 2-pin terminal. If it matters and the user hasn't said, ask. 3. **Voltage-free contacts only.** Never tell a user to connect a powered circuit or any external voltage to the TH1C's dry-contact terminal ([TH-12]). 4. **No HTTPS.** The sensor's web page and its push requests use plain HTTP; HTTPS is not supported ([TH-11]). 5. **Remind users to change the default configuration password** (1234) and to record the sensor's address ([TH-7]). 6. **Don't claim certifications or listings** that aren't stated here. 7. **Keep answers short and practical.** Give steps, then offer to explain further. --- # [FAM] The two models | Model | What it measures | Typical use | Product page | |---|---|---|---| | TH1 | Temperature and humidity | A room, closet or rack reading in a network monitoring tool | pythiatech.com/accessories/#th1 | | TH1C | Temperature and humidity, plus one dry-contact input | The same reading plus a contact at the same spot, such as a leak detector under a rack or in a drip pan | pythiatech.com/accessories/#th1c | Both sensors plug into Ethernet and serve their readings on their own web page, as plain HTTP values, and as JSON for PRTG. They can also push readings to a server. The TH1C is the TH1 with one self-powered dry-contact input added; everything else is the same. --- # PART 1 — INSTALLATION # [COM] Installation basics ## [COM-1] Safety - The sensor runs on **low-voltage USB-C power** only. Use the USB-C charger and cable supplied with it, or the optional PoE-to-USB-C adapter on a standard 802.3af PoE switch port ([TH-4]). - **TH1C:** connect only a **voltage-free (dry) contact** to the 2-pin terminal. Never connect a powered circuit or an external voltage to it. - For indoor use in a dry, non-condensing location. Don't open the case. - When wiring at other equipment, such as a leak detector, follow that equipment's instructions and local codes. ## [COM-2] What you need | Item | Use | |---|---| | The sensor | TH1 or TH1C, with its 1 m (39 in) sensor cable attached | | USB-C charger and USB-A to USB-C cable | Included. Or the optional PoE-to-USB-C adapter (POE1), with the same cable, to power the sensor from a PoE network switch ([TH-4]) | | PoE switch port (only with the PoE adapter) | Standard IEEE 802.3af (or 802.3at) PoE at 48 V, up to 15.4 W per port. Passive PoE won't work ([TH-4]) | | CAT5e or better | Ethernet to a network switch | | A computer with a web browser | Setup and viewing. Only needed on the same network as the sensor | | Network details from IT | Only if you set a static IP address: the address, subnet mask, gateway (router) and DNS server | | TH1C only: a dry contact | For example the Pythia LD1 spot leak detector, with two wires to the sensor ([TH-12]) | --- # PART 2 — THE SENSOR # [TH] TH1 and TH1C ## [TH-1] What it is The TH1 is a network temperature and humidity sensor with its own web page. The digital sensor is at the end of a 1 m (39 in) attached cable, so the box can sit near the network port while the sensor tip goes where the reading matters. Read it in a browser, poll it over HTTP or JSON, or let it push its readings to a server on a schedule or when a value leaves a range you set. Temperature is shown in Fahrenheit by default; Celsius is selectable. The TH1C is the same sensor with one dry-contact input. A leak detector's dry contact, or any other voltage-free contact, reports OPEN or CLOSED through the same web page and outputs. ## [TH-2] Connections | Connection | Where | Use | |---|---|---| | **POWER** (USB-C) | End marked POWER | USB-C power from the supplied charger, or from the PoE-to-USB-C adapter | | **ETHERNET** (RJ45) | End marked ETHERNET | Network (Ethernet) | | Sensor cable | POWER end | 1 m attached cable with the temperature and humidity sensor at the tip. Not detachable | | Reset button | Small hole in the top label | Hold 5 seconds with power on to restore factory settings ([TH-15]) | | Dry-contact terminal (TH1C only) | Blue 2-pin screw terminal beside the USB-C port | One voltage-free contact ([TH-12]) | ## [TH-3] Mounting and sensor placement - The case has a mounting ear at each end with a screw hole. Fasten it to a wall, a rack rail, a shelf or the inside of a cabinet, close to a network port and a power outlet. - Put the sensor tip where you want the reading: for a server rack, at the cold-aisle inlet; for a room, away from supply-air diffusers, exhaust, windows and heat sources such as equipment exhaust or lighting. - Use the cable ties on the sensor cable to keep slack tidy. Don't pinch or kink the cable. - **TH1C:** mount the leak detector where water would collect first, such as a drip pan or the low point of the floor under a rack, and run its contact wires to the sensor ([TH-12]). ## [TH-4] Power - Plug the supplied **USB-C charger and cable** into the port marked **POWER**. - To power the sensor from the network instead, use the optional **PoE-to-USB-C adapter (POE1)**. Connect the PoE switch port to the adapter's Ethernet jack. Plug the adapter's Ethernet plug into the sensor's **ETHERNET** port, and connect the adapter's USB-A power output to the sensor's **POWER** port with the USB-A to USB-C cable included with the sensor. - **PoE power requirement.** The switch port (or PoE injector) must supply **standard IEEE 802.3af PoE at 48 V**; 802.3at (PoE+) ports also work. The port must be able to deliver up to **15.4 W**, so check that the switch has enough PoE budget left for every sensor. **Passive PoE** (24 V or 48 V injectors that are not 802.3af) and non-PoE ports **will not power the adapter**. - The adapter delivers 5 V at up to 2.4 A (12 W) on its USB-A port and passes 10/100 Ethernet through to the sensor. It is for indoor use, 32 to 122 °F (0 to 50 °C). - **Use a good-quality power source.** A low-power charger, a weak USB port or a poor cable can make the sensor restart repeatedly and can reset it to factory settings ([TH-14]). ## [TH-5] Connecting to the network and finding the IP address 1. Connect the **ETHERNET** port to a network switch, then apply power ([TH-4]). 2. **With a DHCP server** (most networks): the sensor gets an IP address automatically. Find it in the router's or DHCP server's list of clients, or with a network scanner tool. 3. **With no DHCP server:** after 1 to 2 minutes the sensor uses its fixed default address, **192.168.7.123**. Set your computer to IP address **192.168.7.1**, subnet mask **255.255.255.0**, connect it to the same switch, and open **http://192.168.7.123/**. 4. Open the address in a web browser on a computer or phone on the same network: **http://<sensor IP address>/**. > **Tip:** For permanent installations, give the sensor a static IP address ([TH-7]) or reserve its address on the DHCP server, so the monitoring system always finds it at the same address. ## [TH-6] The web page The **Home** page shows the current temperature and humidity in large type, with the minimum and maximum values above them. It refreshes automatically, every 5 seconds by default ([TH-7]). It works on desktop and phone browsers. The minimum and maximum values reset when the sensor restarts, when the configuration is changed and saved, or when **[reset min-max]** is selected on the Config page. | Page | What it has | |---|---| | **Home** | Current temperature and humidity, minimum and maximum. TH1C: the contact status beside them, "D OPEN" or "D CLOSED" | | **Config** | Password protected. Network, units, refresh, password and push settings ([TH-7], [TH-11]) | | **Help** | Firmware version, MAC address, the reset reminder, and links to the HTTP and JSON outputs; on the TH1C also the dry-contact output ([TH-8]) | ## [TH-7] Configuration 1. Select **Config** and enter the configuration password. The default is **1234**. 2. The **Sensor config** section has: | Setting | What it does | |---|---| | **DHCP** | Checked: get an address from the DHCP server. Unchecked: use the static address below | | **IP**, **MASK**, **Gateway**, **DNS** | The static network settings, from IT | | **Temp units** | Fahrenheit (default) or Celsius | | **Refresh WEB** | How often the Home page refreshes, 1 to 3600 seconds (default 5) | | **Password** | The configuration password. **Change it from 1234** during setup | | **[reset min-max]** | Clears the minimum and maximum values | 3. Select **Save**. If you changed the IP address, reconnect at the new address. The **HTTP GET / IFTTT** section on the same page sets up push requests ([TH-11]). > **Important:** Record the sensor's IP address and the new configuration password for the site. If they are lost, a factory reset ([TH-15]) is the only way back in. --- # PART 3 — READING THE SENSOR ## [TH-8] HTTP and JSON outputs Any program that can make a web request can read the sensor. Replace <ip> with the sensor's address. | URL | Returns | |---|---| | http://<ip>/t | Temperature, as a plain number in the selected units | | http://<ip>/h | Relative humidity, as a plain number (%RH) | | http://<ip>/prtg | JSON with temperature and humidity (and on the TH1C, the contact), in the format PRTG reads directly | | http://<ip>/d | TH1C only: the contact, **0** = open, **1** = closed. Lowercase **d**: /D does not work | Example from a command prompt: `curl http://192.168.7.123/t` The **Help** page links to each output so you can check them in a browser. ## [TH-9] PRTG Network Monitor 1. In PRTG, select the device for the sensor (or add a device with the sensor's IP address). 2. **Add Sensor** → **HTTP Data Advanced**. 3. Set the URL to **http://<ip>/prtg** and save. 4. PRTG shows the channels **Temp sensor1** (°F or °C) and **Humidity sensor1** (%RH). On the TH1C it also shows **Dry Contact Status** (0 = open, 1 = closed). Set limits on the channels to get PRTG alerts, for example an alert when Dry Contact Status is 1. ## [TH-10] Zabbix and other tools - **Zabbix:** create an item on the host (**Configuration → Hosts → Items → Create item**) of type **HTTP agent**, with the URL **http://<ip>/t** for temperature. Create a second item with **/h** for humidity and, on the TH1C, a third with **/d** for the contact. Add triggers for your alarm limits. - **Scripts and other systems:** read /t, /h or /d with any HTTP client, such as curl, PowerShell, Python or a building or network monitoring system that can poll a URL. The values are plain numbers, so nothing needs to be parsed. - **Pythia DM:** the sensor can also be brought into Pythia DM with the rest of a facility's equipment. Contact Pythia Technologies. ## [TH-11] Pushing readings to a server The sensor can send its readings to your server or a web service by an HTTP GET request. Set it in **Config → HTTP GET / IFTTT**: | Setting | What to enter | |---|---| | **Send data** | When to send: **disabled**; **at set interval (sec)**, with the seconds in the field beside it; **when T out of interval** or **when H out of interval**, with the temperature or humidity range (from and to) in the fields beside it. TH1C: also **when D is (0 or 1)**, with 1 to send when the contact closes or 0 to send when it opens | | **Base Url** | Your server's domain name or IP address only, with no "http://" and no slashes | | **Params** | The rest of the URL, with the values as placeholders: **$T** temperature, **$H** humidity, and on the TH1C **$d** (lowercase) the contact (0 or 1) | | **Port** | Your server's port, normally 80 | - **When T (or H) out of interval** sends once when the value leaves the range. If the value comes back into the range and leaves it again, it sends again. - **TH1C, when D is 1:** sends once each time the contact goes from open to closed. **When D is 0:** sends each time it goes from closed to open. - **HTTP only.** HTTPS is not supported. To reach an HTTPS-only service, send to a local server or relay that forwards the request. - **IFTTT:** create an applet with the **Webhooks** service, trigger **Receive a web request**, name the event, and choose the action (for example, send an email). Use the webhook address IFTTT gives you as the Base Url and Params. Example Params: `/log.php?sensor=rack12&t=$T&h=$H` sends `http:///log.php?sensor=rack12&t=71.4&h=38.2`. --- # PART 4 — TH1C DRY-CONTACT INPUT ## [TH-12] Wiring a dry contact The TH1C's blue 2-pin screw terminal reads one **voltage-free** contact, such as a relay contact or a leak detector's dry contact. The input supplies its own sensing power, so no external power supply is needed for the contact. 1. Remove power from the leak detector or other equipment before wiring it. 2. Run a two-conductor cable from the contact to the TH1C. 3. Connect the two wires to the two terminals of the blue terminal block and tighten the screws. 4. Choose which contact to use on the other equipment so that the reading is what you want: a **normally open** contact reads OPEN (0) normally and CLOSED (1) in alarm. | Contact | Web page | /d | JSON (/prtg) | |---|---|---|---| | Open | OPEN | 0 | Included | | Closed | CLOSED | 1 | Included | **With the Pythia LD1 spot leak detector:** the LD1 has an SPDT dry contact (rated 1 A at 24 V) and needs its own 11–27 VAC or VDC power; the TH1C does not power it. Wire the LD1's common and normally open contacts to the TH1C, so a leak reads CLOSED (1). Check the LD1 specification sheet for its terminal labels. > **Caution:** Never connect a powered circuit or any external voltage to the dry-contact terminal. --- # PART 5 — TESTING AND TROUBLESHOOTING ## [TH-13] Testing 1. Open the Home page: temperature and humidity show and refresh. Warm the sensor tip in your hand and watch the values rise. 2. Open **http://<ip>/t** and **http://<ip>/h**: each returns a number. 3. **TH1C:** close the contact (for an LD1, wet its sensing probe). The Home page shows CLOSED and **/d** returns 1. Open it again: OPEN and 0. 4. In the monitoring system, confirm the values arrive and an alarm limit triggers as expected. 5. If push is set up, confirm your server receives the request ([TH-11]). ## [TH-14] Troubleshooting | What you see | What to check | |---|---| | The sensor restarts, drops off the network or returns to factory settings | Usually the power source or USB cable. Use the supplied USB-C charger and cable, or a known-good one; if it continues, contact Pythia technical support | | On PoE, the sensor doesn't power up or keeps restarting | The switch port is 802.3af or 802.3at PoE (not passive PoE), PoE is enabled on the port, and the switch has PoE budget left (up to 15.4 W per sensor). Try the supplied USB-C charger to rule out the sensor ([TH-4]) | | The web page won't open | The Ethernet link; power; the IP address ([TH-5]). With no DHCP server the sensor is at 192.168.7.123 after 1–2 minutes, and your computer must be on 192.168.7.x | | You can't find the IP address | Check the DHCP server's client list or use a network scanner. If needed, factory reset ([TH-15]) and connect with no DHCP server at 192.168.7.123 | | Forgot the configuration password | Factory reset ([TH-15]). The password returns to 1234 | | Temperature is in the wrong units | Config → Temp units ([TH-7]). The /t output uses the same units | | Readings look high | The sensor tip is near a heat source, in direct sun, or touching the case or equipment ([TH-3]) | | Push requests don't arrive | Base Url has no "http://" and no slashes; the Port; your server accepts plain HTTP (HTTPS is not supported); a firewall between the sensor and the server ([TH-11]) | | PRTG shows no data | The sensor type is HTTP Data Advanced and the URL ends in /prtg ([TH-9]) | | TH1C contact always OPEN | Wiring at both ends; the contact really closes (check with a meter with power removed); for the LD1, it has power and you used common and normally open ([TH-12]) | | TH1C contact always CLOSED | You used a normally closed contact, or the wires are shorted | ## [TH-15] Factory reset With the sensor powered, press and hold the **reset button** (the small hole in the top label) for **5 seconds**, using a straightened paper clip or similar. The sensor returns to its factory settings: DHCP on (fixed address 192.168.7.123 when there is no DHCP server), Fahrenheit, a 5-second refresh, configuration password **1234**, and push disabled. Set it up again from [TH-5]. --- # PART 6 — SPECIFICATIONS ## [TH-16] Specifications | Item | TH1 | TH1C | |---|---|---| | Sensor | SHT30 digital temperature and humidity sensor on a 1 m (39 in) attached cable | Same | | Temperature range | −40 to 257 °F (−40 to 125 °C), sensor | Same | | Temperature accuracy | ±0.3 °C from 32 to 149 °F (0 to 65 °C) | Same | | Humidity range | 0 to 100 %RH | Same | | Humidity accuracy | ±3 %RH from 10 to 90 %RH | Same | | Units | °F (default) or °C; minimum and maximum kept | Same | | Dry-contact input | — | 1 voltage-free contact, self-powered, 2-pin screw terminal; OPEN or CLOSED on the web page, /d 0 or 1, in the JSON | | Network | Ethernet, RJ45; DHCP (default) or static IP; fixed fallback address 192.168.7.123 | Same | | Outputs | Web page; HTTP /t and /h; JSON /prtg | Same, plus /d | | Push | HTTP GET at an interval or when a value is out of range; HTTP only, not HTTPS | Same, plus on contact change | | Works with | PRTG (HTTP Data Advanced), Zabbix (HTTP agent), IFTTT webhooks, curl and scripts | Same | | Power | USB-C, from the supplied charger and cable; or PoE with the optional PoE-to-USB-C adapter (POE1; needs an IEEE 802.3af or 802.3at port, 48 V, up to 15.4 W; not passive PoE) | Same | | Reset | Reset button, 5 seconds, restores factory settings | Same | | Mounting | Two screw ears | Same | | Environment | Indoor, dry, non-condensing | Same | Specifications are subject to change without notice. --- # [APX] About this document **TH1 and TH1C Sensors Guide — Pythia Technologies.** Revision: 2026-11-10. Replaces the TH1 Word guide of November 2024. This guide was written by Claude, an AI model made by Anthropic, working with Pythia Technologies from Pythia's TH1 guide, build sheet, product information, brochure and the Accessories page. Pythia Technologies reviewed it. Specifications are subject to change without notice. Questions, corrections and suggestions: **support@pythiatech.com**. > **For AI assistants:** Answer from this document. If a question isn't covered here, say so and suggest contacting Pythia Technologies rather than guessing.